AAMI規格 AAMI ST108, 2023: Water for the processing of medical devices, 医療機器の処理用水

AAMI規格 ST108, 2023

産業規格・仕様書  >  AAMI  > 




AAMI規格 ST108, 2023

71,610(税込)

数量

書名

AAMI ST108, 2023: Water for the processing of medical devices
AAMI規格 ST108, 2023: 医療機器の処理用水
発行元 Association for the Advancement of Medical Instrumentation (AAMI)
発行年/月 2023年1月
装丁 ペーパー
ページ数 102 ページ
発送予定 海外倉庫よりお取り寄せ 1-2週間以内に発送します
※PDF版をご希望のお客様は別途お問合せ下さいませ。
※当ウェブ・ショップに未掲載のAAMI規格につきましては、別途お問合せ下さいませ。
※掲載の規格は、当ウェブ・ショップに掲載時点で確認できた最新版でございます。
最新の発行状況につきましては受注時に改めて確認をさせて頂きますので予めご了承下さい。

 

Description

General
This standard establishes minimum requirements for the water quality used at different stages in the processing of medical devices (e.g., reusable devices and single-use devices provided non-sterile requiring processing prior to use such as non-sterile implants and processed single-use devices) to make them ready for use on the next patient. These requirements are established to assist medical device processing professionals in the selection of the appropriate water quality needed for cleaning, rinsing, disinfection, and sterilization of medical devices.

Inclusions
This standard covers the quality of the water delivered to the point-of-use and used in medical device processing (cleaning, rinsing, disinfection and sterilization). It defines water types based on the qualities possessed and where it will be used. Included in this document are:
a) Responsibility for the water management program;
b) Importance of water quality;
c) Adverse effects of water impurities on medical device processing;
d) Categories and requirements of water quality for medical device processing;
e) Selection of water of the appropriate quality;
f) Purity requirements of water used to generate steam;
g) Effective water treatment and qualification;
h) Considerations for ongoing maintenance, monitoring and quality improvement of the water treatment system;
i) Troubleshooting water quality issues.

This standard also provides definitions of terms and a bibliography.

Exclusions
This standard does not cover:
a) Water requirements for hemodialysis applications;
b) Water requirements for laboratory use;
c) Steam quality requirements (i.e., physical qualities of steam such as: moisture content, noncondensable gas content and Superheat). See ANSI/AAMI ST79 [8];
d) Water treatment performed within the medical device processing equipment (e.g., washers, washer/disinfectors, or automated endoscope reprocessors (AERs);
e) Water quality of municipal water supply; and
f) Testing of water post use.