IEC規格 60904-10, 3rd Edition, 2020: Photovoltaic devices - Part 10: Methods of linear dependence and linearity measurements

IEC規格 60904-10, 3rd Edition, 2020

産業規格・仕様書  >  IEC  > 




IEC規格 60904-10, 3rd Edition, 2020

55,000(税込)

数量

書名

IEC 60904-10, 3rd Edition, 2020: Photovoltaic devices - Part 10:
Methods of linear dependence and linearity measurements
IEC規格 60904-10, 第3版, 2020: 太陽光発電デバイス - パート10: 線形依存性と線形測定法
発行元 International Electrotechnical Commission (IEC)
発行年/月 2020年9月   
装丁 ペーパー
ページ数 60 ページ
発送予定 海外倉庫よりお取り寄せ 1-2週間以内に発送します
※PDF版 (シングルユーザー)をご希望のお客様は別途お問合せ下さいませ。
※当ウェブ・ショップに掲載のない規格につきましては、別途お問合せ下さいませ。
※掲載の規格は、当ウェブ・ショップに掲載時点で確認できた最新版でございます。 最新の発行状況につきましては受注時に改めて確認をさせて頂きますので予めご了承下さい。


 

Description

This part of IEC 60904 describes the procedures used to measure the dependence of any electrical parameter (Y) of a photovoltaic (PV) device with respect to a test parameter (X) and to determine the degree at which this dependence is close to an ideal linear (straight-line) function. It also gives guidance on how to consider deviations from the ideal linear dependence and in general on how to deal with non-linearities of PV device electrical parameters. Typical device parameters are the short-circuit current ISC, the open-circuit voltage VOC and the maximum power Pmax. Typical test parameters are the temperature T and the irradiance G. However, the same principles described in this document can be applied to any other test parameter with proper adjustment of the procedure used to vary the parameter itself.

Performance evaluations of PV modules and systems, as well as performance translations from one set of temperature and irradiance to another, frequently rely on the use of linear equations (see for example IEC 60891, IEC 61853-1, IEC 61829 and IEC 61724-1). This document lays down the requirements for linear dependence test methods, data analysis and acceptance limits of results to ensure that these linear equations will give satisfactory results. Such requirements prescribe also the range of the temperature and irradiance over which the linear equations may be used. This document gives also a procedure on how to correct for deviations of the short-circuit current ISC from the ideal linear dependence on irradiance (linearity) for PV devices, regardless of whether they are classified linear or non-linear according to the limits set in 9.7. The impact of spectral irradiance distribution and spectral mismatch is considered for measurements using solar simulators as well as under natural sunlight.

The measurement methods described herein apply to all PV devices, with some caution to be used for multi-junction PV devices, and are intended to be carried out on a device, or in some cases on an equivalent device of identical technology, that is stable according to the criteria set in the relevant part of IEC 61215. These measurements are meant to be performed prior to all measurements and correction procedures that require a linear device or that prescribe restrictions for non-linear devices.

The main methodology used in this document is based on a fitting procedure in which a linear (straight-line) function is fitted to a set of measured data points {Xi,Yi}. The linear function uses a least-squares fit calculation routine, which in the most advanced analysis also accounts for the expanded combined uncertainty (k=2) of the measurements. The linear function crosses the origin in the case of short-circuit current data versus irradiance. The deviation of the measured data from the ideal linear function is also calculated and limits are prescribed for the permissible percentage deviation.

Procedures to determine the deviation of the Y(X) dependence from the linear (straight-line) function are described in Clause 6 (measurements under natural sunlight and with solar simulator), Clause 7 (differential spectral responsivity measurements) and Clause 8 (measurements via two-lamp and N-lamp method). Data analyses to determine the deviations from the linear function are given in Clause 9.

A device is considered linear for the specific measured dependence Y(X), when it meets the requirements of 9.7.